Main technical parameters of 95 bit automatic purging and trapping device

source:中儀宇盛   date:2022-04-24 11:25:30   click:
  


The 95 position full-automatic purging and trapping device is a new type of full-automatic purging and trapping device of Beijing Zhongyi Yusheng Technology Co., Ltd. It can be loaded into a 95 position sample bottle once fully loaded, and can be used with all domestic and imported GC and GCMS.

It is suitable for the analysis of volatile organic compounds in liquids and solids, and can also be used for derivative reaction treatment of samples. Liquid sample, sampling to U-tube for purging; For low content solid samples, use 40ml sample bottle to purge directly; For high content solid samples, purge after automatic methanol extraction and dilution.

Types of samples that can be tested: volatile organic compounds in water, wastewater, drinking water, seawater, blood, sediment, slime, soil, cosmetics, textiles, packaging, food, spices, etc.

Main technical parameters

1. Temperature control range of sample tube:

5 ℃ to 80 ℃ above room temperature, set in increments of 1 ℃;

2. Temperature control range of sample cup:

5 ℃ to 80 ℃ above room temperature, set in increments of 1 ℃;

3. Injection needle temperature control range:

5 ℃ to 80 ℃ above room temperature, set in increments of 1 ℃;

4. Temperature control range of GC transmission pipeline:

5 ℃ to 250 ℃ above room temperature, set in increments of 1 ℃;

5. Temperature control range of valve box:

5 ℃ to 250 ℃ above room temperature, set in increments of 1 ℃;

6. Temperature control range of U-shaped purging pipe:

5 ℃ to 80 ℃ above room temperature, set in increments of 1 ℃;

7. Temperature control range of water separator:

5 ℃ to 200 ℃ above room temperature, set in increments of 1 ℃;

8. Temperature control range of pure cleaning water:

5 ℃ to 90 ℃ above room temperature, set in increments of 1 ℃;

9. Trap temperature control range:

150 ℃ to 80 ℃, set in increments of 1 ℃;

10. Trap heating rate:

>2000 ℃ / min, no more than 5% internal overshoot (at 250 ℃);

11. High temperature cooling rate of trap:

Cooling from 250 ℃ to 40 ℃ within 70 seconds;

12. Sample injection accuracy:

RSD < 1% (n = 7), determined by gravimetric method;

13. Selection of sample dilution ratio:

Programmable dilution: 1:100, 1:50, 1:25, 1:10, 1:5, 1:2;

14. Gas flow control range:

5ml / min to 500ml / min;

15. Standard 95 position sample tray (40ml sample bottle) is equipped with sample tray cooling circulating water system to realize low-temperature cooling of sample bottle;


About Us
Company Profile
Appointment interview
corporate culture
Video Center
News
Company dynamics
Common problem
Product
PURGE AND TRAP SERIES
Headspace sampler
Thermal desorption
Gas generator
Consumables and accessories
Contact us
Add:Building 13,Zhongnan High-tech Electronic InformationIndustrial Park,Yanjiao Sanhe Langfang,Hebei,China.
EMAIL:info@bjzyyskj.com.cn
Tel:+86-010-61598028 18857165617 Ms. Yang
Fax:010-61598028-108
WeChat

Scan
Copyright ? 2018 Beijing Zhongyi Yusheng Technology Co., Ltd 京ICP備10046828號(hào)-2
遂溪县| 永春县| 南昌县| 镇雄县| 化隆| 恩平市| 阿尔山市| 濉溪县| 横山县| 苍梧县| 洛宁县| 清流县| 缙云县| 龙州县| 灵川县| 攀枝花市| 浦城县| SHOW| 汽车| 岢岚县| 沙河市| 肥乡县| 乐平市| 乾安县| 渭源县| 潮州市| 张家口市| 娄底市| 许昌市| 兰考县| 江门市| 平乡县| 毕节市| 大足县| 锡林郭勒盟| 军事| 喀喇| 德惠市| 通化县| 蓝山县| 辽源市|